Electromagnetic Anechoic Chamber for In-car Devices
- 8cm high electromagnetic wave absorber (RHFFP) used as high-frequency electromagnetic wave absorber, so that room space can be efficiently used
- Can also support floor earthing type and wall earthing type (removable electromagnetic wave absorber)
Standards Complied | CISPR25 / ISO11452-2 / ISO11452-4 |
---|---|
Size | W6.5 × L9.2 × H4.0 m |
Measurement Distance | 3.0m/1.0m |
Electromagnetic Wave Absorber | RF043+RHFFP absorber or ferrite tile + pyramid ferrite electromagnetic wave absorber (RHFFP series) |
Site Attenuation | 1GHz-18GHz |
Main Shielded Door | W2.0 × H2.0 m semi-automatic sliding door |
Turn Table | --- |